1.1 Peleng SD-01-2000 Base of Cloud Meter
Base of cloud meter (BCM) is designed for measurement of base of cloud (BC) height directly above place of installation.
BCM is a surface instrument of remote sensing consisting of a base of cloud height meter and a PC-based control and display module.
Basic specifications:
-
range of measured base of cloud height from 10 to 2,000 m;
-
basic absolute error of measurement of BC height in the range from 10 to 100 m - ± 10 m;
-
basic relative error of measurement of BC height in the range from 100 to 2,000 m - 10%;
-
power supply 220±22V/50Hz;
-
BCM weight - 50 kg.
Operation conditions:
-
ambient temperature from - 50 to + 50°С;
-
atmospheric pressure from 60 to 108 kPa;
-
relative humidity up to 98% at 35°С;
-
precipitation rate up to 3 mm/min, fog, mist;
-
wind speed up to 55 m/s.
1.2 Airmar WX-150
AIRMAR WX-150 weather station transmits information about weather and vessel location twenty-four hours a day. You may get weather forecast in advance, before vessel departure, by checking the wind speed and direction, temperature and barometric pressure. And know about changes of weather data during trip every minute.
Basic specifications:
-
Wind speed range: 0 knots — 78 knots (0-90 MPH, 0 - 40 m/s)
-
Low wind speed: 0–10 knots; 1 knot RMS +10% of reading (0 - 11.5 MPH; 1.1MPH +10% of reading)
-
High wind speed: 10–78 knots; 2 knots RMS or 5%, whichever is the greater (11.5 - 90 MPH; 2.3 MPH or 5%)
-
Wind direction range: from 0° to 360°
-
Air temperature: from -40°C to 55°C (from -40°F to 131°F)
-
Barometric pressure range: from 300 mbar to 1,100 mbar (from 24 inches to 33 inches, from 800 hPa to 1,100 hPa)
-
Relative humidity range: from 10% to 95% RH-(110WX, 150WX & 200WX)
-
GPS positioning accuracy: 3 m (10 ') with WAAS / EGNOS (95% of time, SA is off) — (150WX & 200WX)
-
Operating temperature range: from -25°C to 55°C (from -13°F to 131°F)
1.3 WXT520 Automatic Weather Station
WXT520 weather station measures six critical weather parameters (wind speed and direction, liquid precipitation volume, atmospheric pressure, temperature and relative humidity), a completely integrated device without moving parts.
Basic specifications:
Operating temperature |
-52 … +60 °C (-60 … +140 °F) |
Storage temperature |
- 60 … +70 °C (-76 … +158 °F) |
Input voltage |
5 … 32 VDC |
Typical rated input |
3 mA at 12 VDC (default settings) |
Heating voltage |
5 … 32 VDC (or AC, max. 30 V mean square) |
Serial communication interface |
SDI-12, RS232, RS485, RS422, USB |
Housing |
IP65 |
Housing with fixing set |
IP66 |
Electromagnetic compatibility |
conforms to IEC EN61326–1 standard, industrial environment |
IEC standards |
IEC 60945/61000–4–2 … 61000–4–6 |
1.4 МК-14–1 Meteorological Package
МК-14–1 meteorological package is designed for automatic measurement of temperature and relative humidity, atmospheric pressure, wind speed and direction.
MK-14-1 is designed for operation at ambient temperatures from -40 to +50°С and relative humidity up to 98%.
Basic specifications:
Measured parameter |
Measurement range |
Limits of admitted absolute error |
Air temperature, °С |
From -20 to +50 |
± 0.25 ± 0.5 |
Relative humidity, % |
From 10 to 98 |
± 5 – basic |
Atmospheric pressure, hPa (mm hg) |
From 800 to 1,100 (from 600 to 825) |
± 0.5 (±0.35) |
Wind speed, V, m/s |
From 0.5 to 5 |
±(0.2 + 0.02)V |
Wind speed, degree |
From 0 to 360 |
± 3.0 |
1.5 Sontek ADP Acoustic Doppler Current Direction and Speed Profiler
Sontek ADP acoustic Doppler current direction and speed profiler is designed for current speed and direction measurement in water column up to 180 meters.
Basic specifications:
-
Maximum number of measurement horizons (cells) – 100.
-
Cell size from 1.0 to 20 meters.
-
Blanking Distance – from 1.5 to 20 meters.
-
Averaging interval from 1 to 43,200 seconds (up to 12 hours).
-
Interval between profiles from 1 to 43,200 seconds (up to 12 hours).
-
Operating frequency - 240 kHz.
-
Recorder memory capacity - 170 Mb.
-
Installation depth - up to 250 m
Parameter |
Range |
Error |
Resolution |
Speed V |
±10 m/s |
±1%V ±0.5 cm/s |
–0.1 cm/s |
Direction |
0° — 360° |
±2° |
0.1° |
Temperature |
from -5° to 45° С |
±0.1С° |
0.01 С° |
1.6 DAD‐А Autonomous Atmospheric Pressure Sensor
DAD‐А autonomous atmospheric pressure sensor is designed for measurement and registration of atmospheric pressure in automatic mode.
Basic specifications:
-
atmospheric pressure measurement in the range from 700 to 1,100 hPa with error ±3 hPa;
-
data recording in non-volatile memory according to the specified period;
-
data output to personal computer with RAD software;
-
DAD - A power source - internal battery, supply voltage 3.5 – 4.2 V;
-
dimensions (length, width, height), max. – 110×55х65 mm;
-
weight, max. - 0.2 kg.
1.7 Lowrance (LCX-15MT) Echo Sounder
Basic specifications:
-
Display: Monochrome Transflective FSTN LCD, black and white image, 16 Grayscale, diagonal — 17.8 cm, resolution — 480×350 pix.
-
Ultrasound signal strength - 4,000 W (at 200 kHz),
-
Maximum depth - 305 m (optional to 915 m).
-
Recording digital and graphical information to MMC/SD to 256 Mb.
-
Two integral water-proof disk drives for MMC/SD.
-
Digital input/output in NMEA0183 format
-
Built-in world maps, ability to work with maps recorded to MMC/SD
-
Basic equipment: monitor, support bracket for monitor installation, transom ultrasound sensor 20 deg/200 kHz with built-in thermometer, support bracket for sensor installation on transom, power/digital communication cable.
1.8 EMIST-1 Package
EMIST-1 package is designed for measurement of current speed and direction, electric conductivity, water temperature and hydrostatic pressure (immersion depth).
EMIST-1 is provided with a sealed connector and can be used in automatic and cable modes. When working with cable up to 1,500 m observation rows of any length can be recorded.
Basic specifications:
Parameter |
Measurement range |
Resolution ability |
Error |
Current speed V, cm/s |
from 2 to 250 |
0.1 |
±(2.0+0.02V) |
Magnetic compass, ° |
from 0 to 360 |
3 |
±5 |
Water temperature, °С |
from – 5 to 35 |
0.01 |
±0.05 |
Electric conductivity, S/m |
from 0.1 to 6.5 |
0.002 |
±0.005 |
Hydrostatic pressure, hPa (depth in m) |
from 50 to 16,000 (0.5 – 160) |
0.4 |
±4 |
1.9 SonTek PC- ADP Acoustic Doppler Current Profiler
The profiler measures current speed and direction in water column of up to 12 metres with vertical resolution of up to 1.6 cm. Maximum number of measurement horizons - 100. Operating frequency - 1.5 MHz.
Basic specifications:
Parameter |
Range |
Error |
Resolution |
Speed V |
±1.5 m/s |
±1%V ±0.1 cm/s |
0.1 cm/s |
Direction |
from 0° to 360° |
±2° |
0.1° |
Temperature |
from -5°C to 45° С |
±0.1С° |
0.01 С° |
1.10 TRITON (SonTek/YSI Triton)
Triton (SonTek/YSI Triton) is a single-point three-dimensional Doppler water flow rate meter developed for monitoring of water flow rare in shallow waters.
Water flow rate is measured at point (sample) located 10 cm above the device housing end.
Basic specifications:
Parameter |
Range |
Accuracy |
Speed, m/s |
0.01 — 600 |
1% |
Pressure, dBar Depth, m |
1 – 60 1 — 60 |
0.1% |
Temperature, ° С |
-5 — 40 |
±0.1°С |
1.11 GMV GMU-2.01 Wave Recorder
GMU-2.01 (GMV wave recorder) is designed for measurement of parameters of heaving, hydrostatic pressure (level) and temperature in the sea coastal areas at depths of up to 25 m. The device is equipped with a sealed connector and can be used in autonomous and cable installations. Autonomous work duration is minimum 2 months with measurement interval of 180 minutes and measurement time of 9 min.
When working with a cable length of up to 1,500 m observation rows of any length can be recorded.
Basic specifications:
Parameter |
Parameter measurement range |
Resolution ability |
Error |
Pressure P, hPa |
100 – 2,500 |
0.1 |
±(0.5+0.002Р) |
Temperature, °С |
from - 5 to + 40 |
0.01 |
±0.05 |
1.12 GMU-2.01А Hydrological Tester (25 metres)
GMU-2.01AM hydrological tester is designed for measurement of hydrostatic pressure (tester) and water temperature during hydrological observations in the sea coastal areas and river outlets.
Basic specifications:
Parameter |
Parameter measurement range |
Sensitivity |
Admitted absolute error limit |
Hydrostatic pressure P, hPa |
50 — 2500 |
0.1 |
±(0.5+0.002Р) |
Temperature, °С |
-5…+40 |
0.01 |
± 0.05 |
1.13 GMU-2.01S (SKLON) Hydrostatic Pressure Tester
GMU-2.01S (SKLON) is designed for measurement of hydrostatic pressure (level) in the sea coastal areas for bottom topography survey.
The tester is working in autonomous mode.
The tester measures water hydrostatic pressure in operating conditions within 40-2,500 hPa at a depth of 0.5 - 25 m.
1.14 GMU-2.02А Hydrostatic Pressure Measuring Transducer
The level meter is designed for measurement of hydrostatic pressure (level) and temperature in the sea coastal areas.
The device is equipped with a sealed connector and can be used in autonomous and cable installations. Autonomous work duration is minimum 3 months with measurement interval of 60 minutes.
When working with a cable length of up to 100 m observation rows of any length can be recorded.
Basic specifications:
Parameter |
Parameter measurement range |
Resolution ability |
Error |
Pressure P, hPa |
from 50 to 15,000 cm |
1 |
±(0.5+0.002Р) |
Temperature, °С |
from - 5 to + 40 |
0.01 |
±0.05 |
1.15 GMU-2.02 Hydrological Tester (350 metres)
GMU-2.02 hydrological tester is designed for measurement of hydrostatic pressure (level) and water temperature during hydrological observations in the sea coastal areas and river outlets.
Basic specifications:
Parameter |
Parameter measurement range |
Admitted absolute error limit |
Hydrostatic pressure Ph, hPa |
100 — 35,000 |
±(5+0.002Р) |
Temperature, °С |
-5…+40 |
± 0.05 |
1.16 GRS-3М Hydrological Package
GRS-3M hydrological package is designed for measurement of water flow rate, temperature, hydrostatic pressure and water electrical conductivity.
Basic specifications:
Parameter |
Measurement range |
Resolution ability |
Admitted absolute error limit ∆а |
Water flow rate V, cm/s |
From 5 to 400 From 5 to 800 |
0.1 0.1 |
±(2.5 +0.02V) ±(2.5 +0.03)V |
Current direction, deg. |
From 0 to 360 |
1 |
±8 |
Water temperature Т ,°С |
From -5 to +40 |
0.01 |
± 0.05 |
Hydrostatic pressure P, hPa |
From 50 to 10,000 (from 50 to 35,000) |
0.1 |
±(0.5 +0.002Р) |
Electrical conductivity (EC), Sm/m |
From 0.1 to 6.5 |
0.0002 |
± 0.005 |
1.17 M-1 Acoustic Release
Acoustic release is designed for remote disconnection of devices installed in autonomous buoy stations.
Basic specifications:
-
Operating temperature range from -5°С to +40°С
-
Maximum immersion depth 700 m
-
Maximum communication distance 2,500 m
-
Autonomous work 3 months
-
Dimensions (805×113*113) mm
-
Weight 18 kg
-
Maximum release hook load 2,000 kg
1.18 EdgeTek Acoustic Release
The devices are designed for remote disconnection when installed in autonomous buoy stations.
Basic specifications:
-
Operating temperature range from -5°С to +30°С;
-
Maximum immersion depth 3,500 m;
-
Dimensions (710×12) cm;
-
Weight 7.5 kg;
-
Maximum release hook load 250 kg.
1.19 RT111 Acoustic Release
The devices are designed for remote disconnection when installed in autonomous buoy stations.
Basic specifications:
-
Operating temperature range from -5°С to +50°С;
-
Maximum immersion depth 6,000 m;
-
Dimensions (780×130*130) mm;
-
Weight 18 kg;
-
Maximum release hook load 5,000 kg.
1.20 SBE 19plus V2 SeaCAT Profile Recorder
SBE 19plus V2 SeaCAT profile recorder is designed for measurement of electric conductivity, temperature and pressure of sea and fresh water at depths of up to 500 metres, and dissolved oxygen, pH, chlorophyll and turbidity.
The device can work in two modes: profiling mode - measurements are continuous at 4 Hz (32,767 averaging measurements); stationary mode - measurements are one time, at intervals from 10 sec to 4 hours.
Basic specifications:
Measured parameter |
Measurement range |
Accuracy |
Temperature, Т°С |
From -5 to +35 |
0.005 |
Electric conductivity, Sm/m |
From 0 to 9 |
0.0005 |
Pressure, dbar |
From 0 to 600 |
0.1% of Р |
рН |
From 9 to 14 |
0.1 |
Dissolved oxygen, ml/l |
From 0 to 15 |
0.1 |
Turbidity, NTU |
From 0 to 1000 |
0.123 NTU |
Chlorophyll, µg/L |
From 0 to 250 |
0.123 µg/L |
1.21 YSI6600 Oceanographic Probe
YSI6600 oceanographic probe is a multi-parameter measuring package which provides measurement, estimate and registration of electric conductivity, salinity, temperature and depth (pressure) of sea and fresh water. Sensors of dissolved oxygen, turbidity and pH can be added to the probe.
Basic specifications:
Sensor |
Units of measurement |
Measurement range |
Resolution |
Error |
Water temperature |
°С |
-5 — 50 |
0.01 |
±0.15 |
Water electric conductivity |
mSm/cm |
0 – 100 |
0.001 |
±0.5% |
рН |
pH |
0 — 14 |
0.01 |
±0.2 |
Pressure |
m |
0 – 200 |
0.001 |
± 0.3 |
Turbidity |
NTU |
0 – 1,000 |
0.1 |
± 2% |
Dissolved oxygen |
mg/L |
0 – 50 |
0.01 |
±(2 – 6)% FS |
1.22 STD-2А Mini probe
STD-2A mini probe is designed for measurement of electric conductivity, water temperature, hydrostatic pressure (immersion depth).
Basic specifications:
Parameter |
Measurement range |
Error |
Electrical conductivity (EC), Sm/m |
From 0.1 to 6.5 |
± 0.004 |
Temperature, °С |
From -5 to + 35 |
± 0.03 |
Hydrostatic pressure Р, kPa |
From 10 to 1,500 (up to 150 m) |
± 0.2% |
Salinity (estimate) |
From 2 to 42 |
|
1.23 SeaBird Oceanographic Probe
SeaBird oceanographic probe is a multi-parameter portable measuring system of autonomous type of average accuracy. The probe registers water temperature and salinity, immersion depth, pH value, turbidity and content of dissolved oxygen, chlorophyll A.
-
Immersion depth - 60 metres.
-
Autonomous work - 48 hours (100 profiles)
-
Information exchange with external device via RS232 interface.
Basic specifications:
Parameter |
Units of measurement |
Measurement range |
Resolution |
Error |
Water temperature |
°C |
from -5 to +35 |
0.01 |
0.010 |
Water electric conductivity |
Sm/m |
0–7 |
0.001 |
0.001 |
pH value |
pH |
0 — 14 |
0.01 |
0.1 |
Pressure |
hPa m |
0 — 6,000 0 — 60 |
0.015%* |
0.25%* |
Turbidity |
FTU/NTU |
0 — 750 |
1%* |
2%* |
Chlorophyll A |
µg/L |
0.03 — 75 0.06 — 150 |
0.03 0.06 |
0.15 0.30 |
Dissolved oxygen |
ml/L |
0 — 15 |
0.01 |
0.1 |
1.24 Trimble 3305 X‐treme DR Tacheometer
Trimble 3305 X‐treme DR tacheometer is designed for routine geodetic surveys.
X‐treme version was specially developed for low temperature applications.
Operating time at low temperatures with a boost battery is 8.5 hours.
DR option enables measurements at up to 70 metres without a reflector.
1.25 CST/berger, SAL 24 Automatic Elevation Meter
Basic specifications:
-
accuracy per 1 km of double stroke 2.0 mm,
-
direct image,
-
zoom 24x, 32x,
-
aperture 36 mm,
-
field of vision 1°20',
-
minimum focusing distance 0.3 m,
-
stadia factor 100,
-
compensator operating range ±15',
-
horizontal circle readability 1°/2g
-
moisture-proof
1.26 KRAZ-255 mounted PBU-2 Drilling Rig
KRAZ-255 mounted PBU-2 Drilling Rig
PBU-2 drilling rig is designed for engineering site investigations and hydrogeological investigations.
Basic specifications:
-
Max. hook load 50 (5100) kN
-
Drilling depth with circulation 100 m, worm conveyors 50 m
-
Max. hole size 190 mm
-
Rod length 1.5 - 3.0, size 50 mm
-
Diesel power 44 (60) kW (hp)
1.27 IMM2 Hydraulic Press
Used to define ice strength properties.
Basic specifications:
-
Generated force: 200 kN.
-
Stroke rate: of piston from 0 to 20 mm/s.
-
Displaceable piston travel: 300 mm.
-
Piston work area: 210 mm.
-
Measurement frequency: 10 Hz.
-
Operating temperature range: from -40 to + 50 °С.
-
Registration system: digital registration with results output to PC in real time mode.
1.28 KOVACS Mechanical Ice Bore (Rototiller) with Cylindrical Core Sampler
KOVAC mechanical ice bore is used for ice sampling with connected special cylindrical core sampler. Ice cores up to 1 meter long are drilled with the core sampler. Core diameter is 14-15 cm.
Extension stems successively installed between the core sampler and the rototiller are used for deep wells drilling.
1.29 GMTsM-1 Hydrometric Mini Flowmeter
GMTsM-1 Hydrometric mini flowmeter is designed for measurement of water flow rate averaged for the period of observations at cross-section points of natural and synthetic stream flows (rivers, channels, pipelines, etc.). The meter can be used for measurement of volumetric water discharge by means of 'current velocity x current area' method and to define the head and delivery characteristics of measuring flumes.
Basic specifications:
velocity measurement range with rated error |
0.05 — 4.0 m/s; |
full range of velocity measurement |
0.03 — 5.999 m/s; |
averaging time (minimum) |
30 sec; |
bladed screw diameter |
0.015 or 0.025 m; |
power supply |
9 V; |
tester weight |
1 kg |
Operation conditions:
air temperature |
from -20 to +50 С; |
water temperature |
up to +45 С; |
water salinity |
up to 1,000 mg/l; |
solids (sand) content |
up to 1 g/L. |